“Laser still plays a very important role in the treatment of diabetic macular edema (DME) despite our reliance on anti-vascular endothelial drugs,” said Elias Reichel, MD.

The Diabetic Retinopathy Clinical Research Network (DRCR.net) Protocol I study bore out this statement in that patients treated with deferred laser therapy, defined as application between 24 weeks, fared the best. Over 2 years, Dr. Reichel pointed out, there was a benefit in those patients compared with those treated promptly with laser and accompanied by anti-VEGF or steroid therapy and sham treatment. In addition, as an additive therapy, laser is helpful even in DRCR.net Protocol T compared with primary VEGF therapy.

Subthreshold laser is defined as that which shows no signs of damage to the clinical examiner, Dr. Reichel explained, and demonstrated what constitutes subthreshold laser therapy. In a patient with 20/50 visual acuity (VA), fluorescein angiography (FA) showed diffuse leakage through the macula, and optical coherence tomography (OCT) showed the cystic change. The patient was treated with micropulse laser in the left eye with the setting of 400 mW, 200-micron spot size, for 200 ms; 343 spots were applied, which is seven applications on a 7 x 7 grid. An important factor in this treatment was the 5% duty cycle, which has been able to perform subthreshold laser treatment safely even with application to the fovea, he emphasized.

Four months after laser treatment, the VA was 20/30. No changes resulting from the treatment or pigmentary changes were visible on fluorescein angiography. The foveal appearance on OCT was more normal than before treatment with some small central cysts visible.

All of the basic science research has supported subthreshold laser; however, the clinical efficacy is supported only by limited case series, which provided data on Micropulse and Endpoint Management (Topcon Medical Systems), he commented. The usefulness of laser demonstrated in the DRCR.net concerned conventional laser photocoagulation only.

“It is important to understand that micropulse therapy can be applied to the fovea in patients with DME, but Endpoint Management and microbubble disruption avoids the fovea,” he said.

FDA-approved devices

The devices approved in the United States all use yellow or green wavelengths. Three micropulse devices have been approved: Micropulse (IRIDEX), Quantel Laser (SubLuminal), and Lumenis (SmartPulse). Topcon makes continuous wave technology (Endpoint Management). Topcon makes continuous wave technology (Endpoint Management). Ellex manufactures Retinal Rejuvenation Therapy [2RT], a microbubble disruption therapy.

Compared with conventional laser, which is characterized by a solid block of laser application over time (100 or 200 ms) accompanied by a temperature increase; the heat produced is absorbed by the retinal pigment epithelium (RPE) and choriocapillaris and is in turn diffused into the neurosensory retina with the potential to cause damage. In contrast, micropulse therapy is a packet of energy that is delivered over 200 ms; the laser is on 5% of the time and off 95% of the time in the individual packets.

“There is an increase in temperature; the retinal tissue heat, but they cool rapidly, and there is no diffusion damage to the neurosensory retina,” Dr. Reichel said.

Endpoint Management differs from Micropulse. “This technology relies on the Arrhenius integral and describes the changes in temperature in time and space over biologic tissues in response to laser energy. This technology uses a short pulse duration within a narrow therapeutic window and the biologic damage is proportional to the laser power,” he explained.
The algorithm used in this technology results in a spot that shows barely visible damage; the power setting then drops 70% to reach the perfect level of treatment energy and duration. Dr. Reichel provided an example in with the energy level was about 30% for 12 ms.

Microbubble disruption provides selective targeting of individual RPE cells. The  microbubbles around the melanosomes expand and cause intracellular damage resulting in individual cell apoptosis. The adjacent RPE cells migrate, divide, and produce new RPE cells.

Dr. Reichel commented that there are no landmark burns in these technologies except for the those produced by the algorithm used in Endpoint Management. The others rely on physician titration, which necessitates that they observe retinal burns.

Practical tips

Dr. Reichel advised that physicians use the correct preset, confirm the correct treatment mode and that the laser is not set to the conventional treatment mode, confirm the 5% duty cycle setting when using Micropulse, and be aware of landmarks and placement of treatment spots.

“Several different subthreshold technologies are available. Administration of subfoveal therapy is only possible with Micropulse. The ability to perform Micropulse and the recommended titration and the appropriate protocol and settings should be confirmed with the manufacturer. No clinical trials have been conducted to confirm the superiority or noninferiority of Micropulse to conventional laser with any of the subthreshold technologies,” Dr. Reichel concluded.

Disclosures:

Elias Reichel, MD

E: ereichel@tufts.nemc.org

Dr. Reichel is a consultant to Lutronics, a member of the speakers’ bureau for IRIDEX, and received a research grant from Lumenis.